Quicktest professional 9.0 license key


















It has an integrated spread sheet Excel like , used for Data driven testing. Data driven Testing: Testing the same task S or same operation with multiple sets of test data. It can be used in two ways. Enter test data directly into Data Table and use. It has two types of sheets. Action Sheets- for specific Action only. Data table available in 2 ways:. Design time data table.

Attached with every test. Run time data table. Available in result window. Run time is a carbon copy of design time data table. QTP has Data table methods for performing operations on data table. It is used for locating and rectifying or fixing errors. It can be used for debugging the tests by step-by-step execution. GetTextLocation test object methods, or the TextUtil. GetText or TextUtil.

GetTextLocation reserved object methods to capture the text you need. Important: The Windows Registry Editor is an advanced tool for changing settings in your system registry.

You should not edit your registry unless absolutely necessary. If there is an error in your registry, your computer may not function properly. The following table lists the possible value entries for the OcrEngine key. Possible Values.

QuickTest will not use the OCR mechanism regardless of the mode value. Same as setting the mode value to 0 - No OCR. Indicates the height or width of the text block in pixels, for example, Modify both value entries to instruct the OCR mechanism to treat the object as a single text block. Note: Sometimes, text on small objects or in a small text area is not captured or is captured incorrectly.

In cases such as these, specifying the maximum text area size in pixels may help improve text recognition. This causes the OCR mechanism to focus on a specific area and treat it as a single text block and not as multiple text blocks, as it would normally do. Default Highly recommended when working with CJK languages. Required when working with Windows Vista. Indicates the language dictionaries that the OCR mechanism uses when retrieving text from the object.

Enter a comma to separate the languages, for example: English,German,Spanish,French. For example: English,Japanese. Indicates the path of the. Note: If the OCR mechanism cannot retrieve any text from the object, you can fine tune its settings to help it recognize the objects in the application being tested. You do this by creating an. Note: Although these text-capturing options and methods are now available for Windows-based objects, keep in mind that any text-recognition mechanism may occasionally capture unwanted text information such as hidden text and shadowed text , or may misinterpret the text content.

Additionally, text-capturing steps may behave differently in different run sessions depending on the operating system version you are using, the installed service packs, other installed toolkits, the APIs used in your application, and so on. Therefore, when possible, it is highly recommended to check text from your application window by inserting a standard checkpoint, output value, or GetROProperty method for the object containing the desired text to retrieve the value of it's text or similar property.

GetText and TextUtil. GetTextLocation reserved object methods are limited and are not always reliable. Click or by using the Set method, a step containing the AcxRadioButton.

GetVisibleText method will return an error stating that the object is not visible. Workaround: Insert a step using the Click or Set methods prior to any step that uses the GetVisibleText method on a "windowless" ActiveX radio button object. Note that when opening a test in this way, you cannot choose whether or not to convert it. Tests are automatically converted to the new format and cannot be opened in earlier versions of QuickTest after they have been converted and saved.

Workaround: Update your automation scripts to use the methods and properties of the ObjectRepositories collection instead. Workaround: Change the value of the property manually or perform an update run operation on the test or component.

These checkpoints may fail during the first run session. Workaround: Insert checkpoints while recording. Workaround: Update the value manually. Otherwise, some data from the ActiveX table will be missing. Workaround: Create ActiveX table checkpoints while recording. For example, date and time values may be set to different formats. Workaround: If you are running the test or component on a different system than the one you used to record the test or component, confirm that the systems use the same format settings.

This is because a hidden property called "windowless" is missing from the test object description. Workaround: You can either relearn the problematic ActiveX controls, or you can add the "windowless" property with a value of 1 to all problematic, windowless ActiveX controls. Note that if you try to install the capture driver from the Screen Recorder Options dialog box while working on one of these operating systems, an error message is displayed.

However, you can use the Mercury Screen Recorder to record and play movies of individual business components created in QuickTest.

This may prevent you from viewing movies associated with defects in Quality Center using the Mercury Micro Player. Workaround: Re-associate the movie files with the Mercury Micro Player, as follows:. These Help files were not prepared by Mercury and Mercury is not responsible for their content. These help files were taken directly from the Microsoft Script The information under the VBScript Reference heading may contain errors, problems, or other limitations.

Mercury makes no representations whatsoever as to the accuracy, adequacy, reliability, currentness, completeness, suitability or applicability of the information under the VBScript Reference heading. Mercury is not responsible for any damages, including the loss of time, which may result from using the information in the help files under the VBScript Reference heading. Workaround: Use the table of contents, index, or search to find the topic you need.

Workaround: Save the patch Readme file locally and open it with Microsoft Internet Explorer or with any text viewer. Workaround: Manually navigate to the required Web site. The Business Process Testing issues described below relate to working with business components and business process tests in QuickTest.

For information on issues related to working with business components in Quality Center , refer to the Quality Center Readme. You can, however, open and view results containing Unicode characters in the QuickTest Test Results window. Otherwise, Quality Center may not be able to open QuickTest. Your email address will not be published. All articles and tutorials on this site are contributed by the expert team under the guidance of Ankur.

Browse by topic: Click any of the links below to jump to each topic on this page. Concurrent License This is a network based license that can be used by multiple users at the same time. To test this scenario manually, you would generally follow these steps — Open web browser Enter the URL of the application. Verify that login is successful Now consider a case where you have to test this login functionality many a times or you have to test the same functionality for large number of different users say a or more users.

This version was able to test websites to ensure they meet the requirements of Section , an amendment to the Rehabilitation Act of QuickTest Professional 6. The major new features added in this version were: Patches on top of version QTP 8. The major new features introduced in this version were: XPath and CSS based object identification Good Looking and Enhanced Results Viewer Easy Regular Expressions Now identify objects not only in relation to each other but in relation to neighboring objects.

This patch has various bug fixes and minor enhancements. It has an added support for Windows 8 and IE With this patch, UFT now fully supports. HP is keeping pace with Firefox.

It has added support for Firefox 21 in this pack. A new method was added for Insight objects: ClickSpecial. This service pack is a mandatory update for all UFT HPE has now added new supported roles for role property in web applications. It enables Selenium users to create and maintain Selenium scripts easily.

UFT documentation is now online by default and not local machine which was the default earlier. However you can still download them to your local machine for faster access. Faster test executions. Accurate highlighting on zoomed web pages. Enhanced AI capabilities. Continued focus on look and feel. How to use javascript in UFT? Should i need to add any Add-ins?

Namrata: Are you using WPF addin with the new sample application? I tried native methods as well but it is throwing me an error. Hi, can I use QC V Hi , I have one question i. Hi, Does UFT Hi Rajveer, This is Rajesh, can you please share me the trick to re-install qtp without formatation. Hi Am new to QTP. Hi, I have scripts developed in QTP 11 version. Many Thanks, Rupali.

This is great information and thanks to you and your team Ankur. I wanted to inform that UFT v We have updated the info accordingly. Hi Shafi, You can valudate xml using xml checkpoint. Does it work? Kindly help. Hi DS did u got solution for your query? Me too facing similar issue. Please help me.

Thank you. Does QTP support Safari? If so until which version it will support? Can you please tell me? Can I use QTP for embedded testing? I really find it very useful. Hi My appplication is dotnet appln. Can anyone tel me what is the problem.. Hi , When i open business components in UFT Prajakta Used different email id and download again. I am using UFT Hope this explains a little.

Very nice info shared about UFT history…Thanks a lot……. Hi, Using QTP, we can login to the application using many users. What is the difference in using both the tools.

Required when working with Windows Vista. Indicates the language dictionaries that the OCR mechanism uses when retrieving text from the object. Enter a comma to separate the languages, for example: English,German,Spanish,French. For example: English,Japanese. Indicates the path of the.

Note: If the OCR mechanism cannot retrieve any text from the object, you can fine tune its settings to help it recognize the objects in the application being tested.

You do this by creating an. Note: Although these text-capturing options and methods are now available for Windows-based objects, keep in mind that any text-recognition mechanism may occasionally capture unwanted text information such as hidden text and shadowed text , or may misinterpret the text content.

Additionally, text-capturing steps may behave differently in different run sessions depending on the operating system version you are using, the installed service packs, other installed toolkits, the APIs used in your application, and so on.

Therefore, when possible, it is highly recommended to check text from your application window by inserting a standard checkpoint, output value, or GetROProperty method for the object containing the desired text to retrieve the value of it's text or similar property. GetText and TextUtil. GetTextLocation reserved object methods are limited and are not always reliable. Click or by using the Set method, a step containing the AcxRadioButton.

GetVisibleText method will return an error stating that the object is not visible. Workaround: Insert a step using the Click or Set methods prior to any step that uses the GetVisibleText method on a "windowless" ActiveX radio button object.

Note that when opening a test in this way, you cannot choose whether or not to convert it. Tests are automatically converted to the new format and cannot be opened in earlier versions of QuickTest after they have been converted and saved. Workaround: Update your automation scripts to use the methods and properties of the ObjectRepositories collection instead. Workaround: Change the value of the property manually or perform an update run operation on the test or component.

These checkpoints may fail during the first run session. Workaround: Insert checkpoints while recording. Workaround: Update the value manually. Otherwise, some data from the ActiveX table will be missing. Workaround: Create ActiveX table checkpoints while recording. For example, date and time values may be set to different formats. Workaround: If you are running the test or component on a different system than the one you used to record the test or component, confirm that the systems use the same format settings.

This is because a hidden property called "windowless" is missing from the test object description. Workaround: You can either relearn the problematic ActiveX controls, or you can add the "windowless" property with a value of 1 to all problematic, windowless ActiveX controls. Note that if you try to install the capture driver from the Screen Recorder Options dialog box while working on one of these operating systems, an error message is displayed.

However, you can use the Mercury Screen Recorder to record and play movies of individual business components created in QuickTest. This may prevent you from viewing movies associated with defects in Quality Center using the Mercury Micro Player.

Workaround: Re-associate the movie files with the Mercury Micro Player, as follows:. These Help files were not prepared by Mercury and Mercury is not responsible for their content. These help files were taken directly from the Microsoft Script The information under the VBScript Reference heading may contain errors, problems, or other limitations.

Mercury makes no representations whatsoever as to the accuracy, adequacy, reliability, currentness, completeness, suitability or applicability of the information under the VBScript Reference heading. Mercury is not responsible for any damages, including the loss of time, which may result from using the information in the help files under the VBScript Reference heading.

Workaround: Use the table of contents, index, or search to find the topic you need. Workaround: Save the patch Readme file locally and open it with Microsoft Internet Explorer or with any text viewer. Workaround: Manually navigate to the required Web site. The Business Process Testing issues described below relate to working with business components and business process tests in QuickTest.

For information on issues related to working with business components in Quality Center , refer to the Quality Center Readme. You can, however, open and view results containing Unicode characters in the QuickTest Test Results window. Otherwise, Quality Center may not be able to open QuickTest. Workaround : To rename a test or component, open it in QuickTest and rename it using the Save As option.

If the test or component has already been renamed from Quality Center , use the rename option again to restore the old name, and then use the Save As option in QuickTest. Renaming a QuickTest test parameter from QuickTest will cause any run-time parameter values already set for this parameter in Quality Center to be lost.

Doing so may corrupt that business component. Workaround: After converting the business component, you must associate it with an application area that contains the required resources and settings.

Any required settings must be defined in the QuickTest test settings. When using the LoadRunner Scheduler, the number of passed iterations shown in the Vusers window of the LoadRunner Controller is inaccurate. Workaround: Display the fonts for these languages at 22 points or higher. Workaround: Set the hardware acceleration of the display driver to None.

If this does not work, uninstall the VMware display adapter. Note that you may need to restart your computer after setting this option. This may result in a loss of data during the run session. Workaround : Run an Activate method on the application's window to ensure focus on the window before performing the next step.

For example:. Window "Notepad". Workaround : Avoid performing mouse operations on the IME window during recording. Workaround: Do not include a step that closes a Mozilla Firefox browser. Hi, What is the system requirements for QTP 9.



0コメント